Developed for integrators, designed to be robust so they are reliable in the field and easy to set up
This bidirectional gateway provides a straightforward and fast integration thanks to its unique onboard features. Thanks to its support for custom ASCII strings, seamless integration with any ASCII BMS or controller is guaranteed.
The configuration is carried out using the Intesis MAPS software. This one allows you to define your own settings for the device. Also, it will be able to download all the available project templates or to import any created/exported project template on your computer.
Integrate any BACnet MS/TP or BACnet IP server device, with an ASCII BMS or any ASCII IP or ASCII serial controller. The aim of this integration is to make accessible BACnet objects data and resources from an ASCII based control system or device as if it was a part of the own ASCII system and vice-versa.
BACnet Protocol Translators
Our BACnet solutions have been specially designed to allow supervision and bidirectional control of systems and equipment talking BACnet, DALI, KNX, LonWorks, M-Bus, and Modbus protocols.
On the BACnet server versions, the gateway provides server functionality to the BMS or BACnet controller over BACnet/IP through the Ethernet port and over BACnet MS/TP through the serial port.
On the BACnet client versions, the gateway provides client functionality to control BACnet IP server devices through Ethernet and BACnet MSTP devices through the serial port. In such cases, control and monitoring of BACnet devices from ASCII, KNX, and Modbus BMS controllers is possible.
- Great integration flexibility thanks to KNX TP, LonWorks, RS485, Ethernet, DALI, or M-Bus interfaces.
- Scaled licenses per number of datapoints help to find the right gateway version for your project.
- Conforms to BACnet revision 14, B-AAC Profile.
- Supports BI, BO, AI, AO, Device, BV, AV, MI, MO, MV, NC, Schedule, and Calendar BACnet objects.
- Supports subscription requests (COV).
- BTL certified.
BACnet IP and MSTP
The device can communicate through Ethernet or serial ports with BACnet IP or BACnet MSTP networks.
BBMD and foreign Devices
BACnet devices can work in complex BACnet/IP networks, providing the ability to communicate between subnets or/and through routers.
Advanced features
All Intesis BACnet Servers allow hosting notification class, calendar, schedule, and trend log objects as well as support for subscription requests (COV).
BTL certified
It provides an assurance that products have been independently tested and have passed industry-standard BACnet testing.
ASCII Protocol Translators
Intesis ASCII gateways offer control and monitoring of BACnet or KNX devices from any ASCII Client (BMS, PLC, or SCADA).
Intesis ASCII gateways could communicate through IP and serial (RS232 or RS485) interfaces and offer great flexibility to communicate with any ASCII system thanks to the use of custom string commands and custom string signals to match each system’s specifications.
Intesis ASCII solutions act as an ASCII Server, so it waits for any query and responses according to the message received. Whenever an internal data point changes its value, the gateway could send an ASCII message informing about the new value too.
- Easy integration through KNX TP, RS485, Ethernet, and serial ports with BACnet and KNX protocols.
- Scaled licenses per number of datapoints help to find the right gateway version for your project.
Both ASCII Serial & IP supported
All ASCII gateways can communicate through Serial (RS232 & RS485) and TCP ports at the same time.
Custom string signals
It offers great flexibility to adapt to different devices, BMS, or systems defining custom ASCII strings per each signal.
Custom string commands
It offers great flexibility to adapt to different devices, BMS, or systems selecting custom string commands on Intesis MAPS software.
Value changed notifications
Gateway will report all changes in signals with this parameter active. It helps to improve communications and refresh time of the system.
Product Information
- UL Certified
- BTL Certified
- Support for both ASCII IP and ASCII Serial (232/485)
- Automatically send a written request to the ASCII bus when its value changes
- Use personalized ASCII strings
- Both BACnet IP and MS/TP supported
- Possibility to scan for BACnet devices with BACnet Explorer
- Easy integration & updates with Intesis MAPS
ORDER CODES:
INASCBAC6000000 | BACnet IP & MS/TP Client to ASCII IP & Serial Server Gateway – 600 points |
INASCBAC3K00000 | BACnet IP & MS/TP Client to ASCII IP & Serial Server Gateway – 3000 points |
- Intesis Gateway.
- Installation Manual.
- USB Configuration cable.
- (Power supply not included).
- Warranty: 36 months.
Book your product
We are fully committed to providing our customers with the very best products and customer service. We believe in going the extra mile to ensure that each customer is satisfied with our products and solutions. We have the experience and the reputation in the field to deliver the products customers need to expedite their projects and assure quality every step of the way.
Our expertise lies in establishing, maintaining, and leveraging plant data for business benefit. Through our innovative solutions, we work alongside you to streamline processes, enhance efficiency, and reduce costly downtime.
CONTACT US
Main: +27 (11) 548 9960
Sales: +27 (11) 548 9970
SOCIAL MEDIA