Perfect for long cable distances and galvanic isolation between devices and segments
The Anybus PROFIBUS Fibre Optic module is a unique product that allows long cable distances and galvanic isolation between devices and segments. This module is perfectly suitable for point-to-point-, bus-, star- and hub topologies. Because bus monitor data is directly available in the web server, the Fibre Optic module allows technicians to optimal maintenance on a PROFIBUS installation.
The Fibre Optic modules can be placed side by side with repeater modules. Just like any other communication module, the channels are connected directly to the ProfiTrace OE core in the Head Station.
ComBricks can also easily be transformed into a fully dedicated fibre optic hub mixed with copper segments. The hub topology delivers an optimised delay time and enables live expansion. The advanced 12 Mbps core of the fibre optic module can be cascaded unlimitedly with other fibre modules. It contains diagnostic LEDs and supports the redundancy feature.
Product Information
Distinctive features
Figure 2 – Fiber optic topologies
Dimensions
L x W x H: | 146 x 25 x 101 mm (including backplane) |
Weight: | 121 g (excluding plug-able fibre optic connector and packing material) |
Mounting DIN-rail type | 35mm × 7,5mm (EN 50022, BS 5584, DIN 46277-3) |
Ambient conditions
Operating temperature range |
0° to +60° Celsius (for mounting position see manual) 32° to +140° Fahrenheit |
Isolation class | IP 20 (IEC/EN 60529, DIN 40050) |
Backplane
PROFIBUS networks | 4 (set by dipswitches or web server) |
Modules | Max. 10 (positioned in the first 10 slots) |
Power supply | Provided through the backplane |
Typical backplane current at 5.75 VDC | 360 mA (at 5.72 VDC) |
Max. backplane current at 5.75 VDC | 510 mA (at 5.72 VDC) At this current consumption the module is switched OFF from the backplane. Occurs when the module is faulty, e.g. internal short circuit. |
Compatible backplane units |
101-200011, 101-200022, 101-200023, 101-200024, 101-200027 |
Head Station firmware | 1.264 and higher |
Protocol specifications
Supported Protocols | DP-V0, DP- V1, DP-V2, FDL, MPI, FMS, PROFIsafe, PROFIdrive and any other FDL-based protocol | ||||||||||||||||||||||||||||||||||||||||||||
Address | No bus address required | ||||||||||||||||||||||||||||||||||||||||||||
Transmission speed | 9.6 kbps … 12 Mbps (including 45.45 kbps) | ||||||||||||||||||||||||||||||||||||||||||||
Transmission speed detection time | Auto detect (< 10 s detection and 50 s baudrate switchover time) | ||||||||||||||||||||||||||||||||||||||||||||
The total delay ring structure |
TSLOT ≥ MaxTSDR + ((FOlength FOlength = Total length of fibre optic cable in the ring in km FOdelay = Delay of fibre optic cable per km in bit times (see table) NFO-modules = Number of fibre optic modules in the ring Ndelay = Delay of one fibre optic module (see table) The delay time is multiplied by 2 for a request and response message.
Note FOdelay = (FOcable_length / FOcable latency ) / Bittime example FOdelay, 1km, 1.5Mbps: (1000 m / 200 µsec/m) / 0.666 µsec = 7.5 Tbit/km Example 1: 1.5 Mbps, 5 km FO cable (total ring length), 6 FO ring modules TSLOT ≥ MaxTSDR + ((FOlength x FOdelay) + (NFO-modules x Ndelay)) x 2 TSLOT ≥ 150 + ((5 x 7.5) + (6 x 9)) x 2 ≥ 333 bit times Example 2: 6 Mbps, 25 km FO cable (total ring length), 10 FO ring modules TSLOT ≥ MaxTSDR + ((FOlength x FOdelay) + (NFO-modules x Ndelay)) x 2 TSLOT ≥ 450 + ((25 x 30) + (10 x 25)) x 2 ≥ 2450 bit times |
||||||||||||||||||||||||||||||||||||||||||||
Jitter per message frame |
0.0625 Tbit at 9.6 Kbps – 3 Mbps 0.125 Tbit at 6 Mbps 0.25 Tbit at 12 Mbps |
||||||||||||||||||||||||||||||||||||||||||||
Deviation | 2 Tbit times for received messages is allowed and is corrected to nominal speed when transmitted (over the complete message) |
Fibre optic specifications
Fibre Optic wavelength | Multimode 850 nm (Compatible with most other vendors in 3rd party compatibility mode) |
Cable type |
Multimode Fibre G62.5 / 125 µm (OM1 compatible) Multimode Fibre G50 / 125 µm (OM2, OM3, OM4, OM5 compatible) |
Cable length | Max. 3 km (baudrate independent) |
Connectors | 4 x ST/BFOC (2 channels) |
Topologies | Point-to-point, Star and Bus |
Cascading depth | No limit, only busparameter limitation of the master |
Redundancy | Maximum 10 cables activated by Dip-Switch |
Dipswitches
NW0 NW1 RED H/S |
PROFIBUS Network Settings |
---|
LEDs
OFF | Blinking | ON | |
RDY | Module has NOT been powered / initialised yet. | Head Station is initialising or updating the module. | Module has been initialised and is operational |
RX1 / RX2 | NO signal, or NO valid telegrams detected on this channel, or channel is off. | 1 or more devices are communicating on this channel. | A fibre optic cable is connected and link is established correctly |
LV1 / LV2 | Signal quality is good, or channel is off. | Not possible | Low signal, received messages can still be decoded |
ER1 / ER2 | No errors, or channel is off. | Not possible | No baudrate detected or no connection/signal |
Standard and approvals
CE |
EMC Directive 2014/30/EU, class B Digital Device RoHs Directive 2011/65/EU |
FCC | 47 CFR 15, Unintentional Radiator, class B Digital Device. |
UL |
Report reference: E468970 Standards for safety: UL 508 – Industrial Control Equipment CSA C22.2 No. 142-M1987 – Industrial Control Equipment Complies with 21 CFR 1040.10 and 1040.11, Class 1 (I) except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007 |
Order Codes | 101-201510 |
Included Components | Anybus ComBricks, backplane socket |
Warranty | 1 year |
Book your product
We are fully committed to providing our customers with the very best products and customer service. We believe in going the extra mile to ensure that each customer is satisfied with our products and solutions. We have the experience and the reputation in the field to deliver the products customers need to expedite their projects and assure quality every step of the way.
Our expertise lies in establishing, maintaining, and leveraging plant data for business benefit. Through our innovative solutions, we work alongside you to streamline processes, enhance efficiency, and reduce costly downtime.
Copyright @2024 Industrial Data Xchange.
All rights reserved.
CONTACT US
Main: +27 (11) 548 9960
Sales: +27 (11) 548 9970
SOCIAL MEDIA