Developed for integrators, designed to be robust so they are reliable in the field and easy to set up
This bidirectional gateway provides a straightforward and fast integration thanks to its unique onboard features. Thanks to its support for both Modbus RTU and TCP, with the possibility to work together at the same time, seamless integration with any Modbus BMS or controller is guaranteed.
The configuration is carried out using the Intesis MAPS software. This one allows you to define your own settings for the device. Also, it will be able to download all the available project templates or to import any created/exported project template on your computer.
Integrate any BACnet MS/TP or BACnet IP server device, with a Modbus BMS or any Modbus TCP or Modbus RTU controller. The aim of this integration is to make accessible BACnet objects data and resources from a Modbus based control system or device, as if it was a part of the own Modbus system and vice-versa.
BACnet Protocol Translators
Our BACnet solutions have been specially designed to allow supervision and bidirectional control of systems and equipment talking BACnet, DALI, KNX, LonWorks, M-Bus, and Modbus protocols.
On the BACnet server versions, the gateway provides server functionality to the BMS or BACnet controller over BACnet/IP through the Ethernet port and over BACnet MS/TP through the serial port.
On the BACnet client versions, the gateway provides client functionality to control BACnet IP server devices through Ethernet and BACnet MSTP devices through the serial port. In such cases, control and monitoring of BACnet devices from ASCII, KNX, and Modbus BMS controllers is possible.
- Great integration flexibility thanks to KNX TP, LonWorks, RS485, Ethernet, DALI, or M-Bus interfaces.
- Scaled licenses per number of datapoints help to find the right gateway version for your project.
- Conforms to BACnet revision 14, B-AAC Profile.
- Supports BI, BO, AI, AO, Device, BV, AV, MI, MO, MV, NC, Schedule, and Calendar BACnet objects.
- Supports subscription requests (COV).
- BTL certified.
BACnet IP and MSTP
The device can communicate through Ethernet or serial ports with BACnet IP or BACnet MSTP networks.
BBMD and foreign Devices
BACnet devices can work in complex BACnet/IP networks, providing the ability to communicate between subnets or/and through routers.
Advanced features
All Intesis BACnet Servers allow hosting notification class, calendar, schedule, and trend log objects as well as support for subscription requests (COV).
BTL certified
It provides an assurance that products have been independently tested and have passed industry-standard BACnet testing.
Modbus Protocol Translators
Bring connectivity to your Modbus management system thanks to Intesis Modbus solutions. Connect BACnet, KNX, LonWorks, DALI, or M-BUS devices to Modbus systems and extend your building management system capabilities.
Intesis Modbus can act as a Modbus RTU device, Modbus TCP device, or both.
On the Modbus server versions, the gateway provides server functionality to the BMS or Modbus controller over Modbus TCP through the Ethernet port and over Modbus RTU through the serial port (EIA485 or EIA232).
On the Modbus client versions, the gateway provides client functionality to control Modbus TCP server devices through Ethernet and Modbus RTU devices through the serial port. In such cases, control and monitoring of Modbus devices from BACnet and KNX BMS controllers is possible.
- Great integration flexibility thanks to KNX TP, RS485, Ethernet, DALI, or M-Bus interfaces.
- Scaled licenses per number of datapoints help to find the right gateway version for your project.
- Modbus advanced functionalities to improve internal and external protocol communications.
- Modbus template repository with most common Modbus devices and template generator to create your own template devices.
Modbus TCP & RTU
All Modbus gateways can communicate with Modbus TCP and RTU networks at the same time.
Most I/O Modbus functions supported
Use any I/O function code of the wide range supported by Modbus gateways (1x, 2x, 3x, 4x, 5x, 6x, 15x, and 16x).
Multiple data formats
Configure the data length (1, 16, 32, 48, or 64 bits), format (unsigned, signed, float, and bitfield), and byte order (big or little-endian).
Polling groups
Improve Modbus communications grouping register requests per device, asking multiple registers in a single request.
Product Information
- UL CertifiedBTL Certified
- Support for up to 5 simultaneous Modbus TCP Clients
- Both Modbus RTU & Modbus TCP
- Both BACnet IP and MS/TP supported
- Possibility to scan for BACnet devices with BACnet Explorer
- Easy integration & updates with Intesis MAPS
ORDER CODES:
INMBSBAC1000000 | BACnet IP & MS/TP Client to Modbus TCP & RTU Server Gateway – 100 points |
INMBSBAC2500000 | BACnet IP & MS/TP Client to Modbus TCP & RTU Server Gateway – 250 points |
INMBSBAC6000000 | BACnet IP & MS/TP Client to Modbus TCP & RTU Server Gateway – 600 points |
INMBSBAC1K20000 | BACnet IP & MS/TP Client to Modbus TCP & RTU Server Gateway – 1200 points |
INMBSBAC3K00000 | BACnet IP & MS/TP Client to Modbus TCP & RTU Server Gateway – 3000 points |
- Intesis Gateway.
- Installation Manual.
- USB Configuration cable.
- (Power supply not included).
- Warranty: 36 months.
Book your product
We are fully committed to providing our customers with the very best products and customer service. We believe in going the extra mile to ensure that each customer is satisfied with our products and solutions. We have the experience and the reputation in the field to deliver the products customers need to expedite their projects and assure quality every step of the way.
Our expertise lies in establishing, maintaining, and leveraging plant data for business benefit. Through our innovative solutions, we work alongside you to streamline processes, enhance efficiency, and reduce costly downtime.
Copyright @2024 Industrial Data Xchange.
All rights reserved.
CONTACT US
Main: +27 (11) 548 9960
Sales: +27 (11) 548 9970
SOCIAL MEDIA