Specifically designed to allow bidirectional control and monitoring of all parameters and functionalities of your building automation projects
This bidirectional gateway provides a straightforward and fast integration thanks to its unique onboard features.
Thanks to its support for both Modbus RTU and TCP, with the possibility to work together at the same time, seamless integration with any Modbus BMS or controller is guaranteed.
The configuration is carried out using the Intesis MAPS software. This one allows you to define your own settings for the device. Also, it will be able to download all the available project templates or to import any created/exported project template on your computer.
Integrate any DALI/DALI-2 driver and DALI-2 light sensor, or occupancy sensor with a Modbus BMS or any Modbus TCP or Modbus RTU controller. The aim of this integration is to make DALI devices and their data and resources accessible from a Modbus based control system or device as if it was a part of the own Modbus system and vice-versa.
DALI Protocol Translators
Control, monitor, and commission DALI installations thanks to Intesis DALI solutions and make it available from any BACnet, KNX, or Modbus management system.
Intesis DALI gateway acts as an application controller master device in its DALI interface and supplies power to the channel, allowing interaction and commissioning of DALI drivers or DALI-2 drivers and occupancy and light sensors as input devices. Control individually up to 64 or 128 DALI addresses and/or up-to 16 or 32 DALI Groups, including the usage of 16 scenes.
- Easy integration through KNX TP, BACnet, or Modbus protocols.
- Support for individual level, group, and broadcast DALI commands.
- Support for Emergency Lighting Systems using advanced functions like Auto testing lamps, Part 202.
- Support for DALI-2 occupancy and light sensors as input devices, parts 103, 303, and 304.
Embedded DALI power supply
No additional hardware is needed, required DALI power supply per each DALI channel is embedded.
DALI-2 support
Ensure interoperability between different sensors and drivers thanks to DALI-2 support.
Support for different driver types
Integrate and configure the specific parameters for Fluorescence, LED, or Emergency lightings in compliance with parts 102, 201, 202, and 207.
Occupancy and brightness sensors
Integrate and configure the specific parameters for occupancy and brightness sensors, in compliance with parts 103, 303, and 304.
Modbus Protocol Translators
Bring connectivity to your Modbus management system thanks to Intesis Modbus solutions. Connect BACnet, KNX, LonWorks, DALI, or M-BUS devices to Modbus systems and extend your building management system capabilities.
Intesis Modbus can act as a Modbus RTU device, Modbus TCP device, or both.
On the Modbus server versions, the gateway provides server functionality to the BMS or Modbus controller over Modbus TCP through the Ethernet port and over Modbus RTU through the serial port (EIA485 or EIA232).
On the Modbus client versions, the gateway provides client functionality to control Modbus TCP server devices through Ethernet and Modbus RTU devices through the serial port. In such cases, control and monitoring of Modbus devices from BACnet and KNX BMS controllers is possible.
- Great integration flexibility thanks to KNX TP, RS485, Ethernet, DALI, or M-Bus interfaces.
- Scaled licenses per number of datapoints help to find the right gateway version for your project.
- Modbus advanced functionalities to improve internal and external protocol communications.
- Modbus template repository with most common Modbus devices and template generator to create your own template devices.
Modbus TCP & RTU
All Modbus gateways can communicate with Modbus TCP and RTU networks at the same time.
Most I/O Modbus functions supported
Use any I/O function code of the wide range supported by Modbus gateways (1x, 2x, 3x, 4x, 5x, 6x, 15x, and 16x).
Multiple data formats
Configure the data length (1, 16, 32, 48, or 64 bits), format (unsigned, signed, float, and bitfield), and byte order (big or little-endian).
Polling groups
Improve Modbus communications grouping register requests per device, asking multiple registers in a single request.
Product Information
- UL Certified
- DALI-2 Certified
- Support for up to 5 simultaneous Modbus TCP Clients
- Both Modbus RTU & Modbus TCP
- Support for DALI & DALI-2 drivers & DALI-2 sensors
- Integrated DALI power supply
- Up to 2 DALI channels
- Up to 64 drivers/ballasts + 16 DALI-2 sensors per channel (Guaranteed DALI supply: 235mA)
- Easy integration & DALI commissioning with Intesis MAPS
ORDER CODES:
INMBSDAL0640200 | DALI to Modbus TCP & RTU Server Gateway – 1 channel |
INMBSDAL1280200 | DALI to Modbus TCP Server Gateway – 2 channels |
- Intesis Gateway.
- Installation Manual.
- USB Configuration cable.
- Warranty: 36 months.
Book your product
We are fully committed to providing our customers with the very best products and customer service. We believe in going the extra mile to ensure that each customer is satisfied with our products and solutions. We have the experience and the reputation in the field to deliver the products customers need to expedite their projects and assure quality every step of the way.
Our expertise lies in establishing, maintaining, and leveraging plant data for business benefit. Through our innovative solutions, we work alongside you to streamline processes, enhance efficiency, and reduce costly downtime.
Copyright @2024 Industrial Data Xchange.
All rights reserved.
CONTACT US
Main: +27 (11) 548 9960
Sales: +27 (11) 548 9970
SOCIAL MEDIA