Select Page

Specifically designed to allow bidirectional control and monitoring of all parameters and functionalities of your building automation projects

This bidirectional gateway provides a straightforward and fast integration thanks to its unique onboard features. Thanks to its support for both Modbus RTU and TCP, with the possibility to work together at the same time, a seamless integration with any Modbus BMS or controller it is guaranteed.

The configuration is carried out using the Intesis MAPS software. This one allows you to define your own settings for the device. Also, it will be able to download all the available project templates or to import any created/exported project template on your computer.

Integrate any KNX device or installation, with a Modbus BMS or any Modbus TCP or Modbus RTU controller. The aim of this integration is to make accessible KNX communication objects and resources from a Modbus based control system or device, as if it was a part of the own Modbus system and vice-versa.

KNX Protocol Translators

Provide BACnet, DALI, M-Bus, or Modbus communication to your KNX installations. Intesis KNX solutions offer a perfect integration in any KNX project thanks to the availability of multiple standard DPT (Data Point Types) and our expertise in KNX solutions.

Intesis KNX connects directly to the KNX TP-1 bus and behaves like any other device in the KNX system, with the same configuration and operational characteristics as other KNX devices.

  • Great integration flexibility thanks to KNX TP, RS485, Ethernet, DALI, or M-Bus interfaces.
  • Scaled licenses per number of datapoints help to find the right gateway version for your project.

Standard KNX Datapoint Types

It ensures interoperability and data quality between different manufacturers’ devices.

Extended group addresses

In big projects actívate extended group addresses and use up to 32 main group addresses in a 3-Level configuration.

Sending and listening addresses

Every point can be addressed not only using its main group address but also using the other defined listening addresses for the point.

Ri flag (Read on initialisation flag)

In order to get updated data as soon as possible, KNX gateways could requests updated data to the bus after initialisation, instead of waiting for changes.

Modbus Protocol Translators

Bring connectivity to your Modbus management system thanks to Intesis Modbus solutions. Connect BACnet, KNX, LonWorks, DALI, or M-BUS devices to Modbus systems and extend your building management system capabilities.

Intesis Modbus can act as a Modbus RTU device, Modbus TCP device, or both.

On the Modbus server versions, the gateway provides server functionality to the BMS or Modbus controller over Modbus TCP through the Ethernet port and over Modbus RTU through the serial port (EIA485 or EIA232).

On the Modbus client versions, the gateway provides client functionality to control Modbus TCP server devices through Ethernet and Modbus RTU devices through the serial port. In such cases, control and monitoring of Modbus devices from BACnet and KNX BMS controllers is possible.

  • Great integration flexibility thanks to KNX TP, RS485, Ethernet, DALI, or M-Bus interfaces.
  • Scaled licenses per number of datapoints help to find the right gateway version for your project.
  • Modbus advanced functionalities to improve internal and external protocol communications.
  • Modbus template repository with most common Modbus devices and template generator to create your own template devices.

Modbus TCP & RTU

All Modbus gateways can communicate with Modbus TCP and RTU networks at the same time.

Most I/O Modbus functions supported

Use any I/O function code of the wide range supported by Modbus gateways (1x, 2x, 3x, 4x, 5x, 6x, 15x, and 16x).

Multiple data formats

Configure the data length (1, 16, 32, 48, or 64 bits), format (unsigned, signed, float, and bitfield), and byte order (big or little-endian).

Polling groups

Improve Modbus communications grouping register requests per device, asking multiple registers in a single request.

Product Information

  • UL Certified
  • Support for up to 5 simultaneous Modbus TCP Clients
  • Both Modbus RTU & Modbus TCP
  • Support for KNX TP devices.
  • Control up to 3000 KNX communication objects
  • Easy integration & updates with Intesis MAPS
 

  • ORDER CODES: 
    INMBSKNX1000000  KNX TP to Modbus TCP & RTU Server Gateway – 100 points
    INMBSKNX2500000  KNX TP to Modbus TCP & RTU Server Gateway – 250 points
    INMBSKNX6000000  KNX TP to Modbus TCP & RTU Server Gateway – 600 points
    INMBSKNX1K20000  KNX TP to Modbus TCP & RTU Server Gateway – 1200 points
    INMBSKNX3K00000  KNX TP to Modbus TCP & RTU Server Gateway – 3000 points
  • Intesis Gateway.
  • Installation Manual.
  • USB Configuration cable.
  • (Power supply not included).
  • Warranty: 36 months.

Book your product

We are fully committed to providing our customers with the very best products and customer service. We believe in going the extra mile to ensure that each customer is satisfied with our products and solutions. We have the experience and the reputation in the field to deliver the products customers need to expedite their projects and assure quality every step of the way.

Our expertise lies in establishing, maintaining, and leveraging plant data for business benefit. Through our innovative solutions, we work alongside you to streamline processes, enhance efficiency, and reduce costly downtime.

Copyright @2024 Industrial Data Xchange.
All rights reserved.

CONTACT US

Main: +27 (11) 548 9960
Sales: +27 (11) 548 9970

SOCIAL MEDIA