Connect non-industrial devices with a CAN-based protocol to CANopen
Integrate your CAN-based industrial devices and equipment to a CANopen control system without the need for any changes to the device. Just connect, configure and you’re done!
The Anybus Communicator is a proven and trusted protocol converter gateway that connects non-industrial devices with a CAN-based protocol to CANopen. The gateway performs intelligent protocol conversion and presents the CAN data to the Master PLC/Controller as easily processed I/O data.
The Anybus AB7315 Communicator
The Communicator is a slim stand-alone gateway designed for IP20 and DIN-rail mounting, requiring a 24-volt power supply. The Communicator is conformance tested to current PROFINET-IRT specifications guaranteeing network compatibility.
Typical CAN applications
Typical serial applications include variable frequency drives, sensors, actuators, human-machine interfaces, bar code readers, RFID readers, and industrial scales among others.
Product Information
- CAN protocol converter gateways connecting CAN devices to Fieldbus/Ethernet networks
- Support for custom CAN 1.0, 2.0A, and 2.0B protocols
- Handles mixed Produce/Consume and Request/Response protocols and transactions
- No hardware or software changes needed to your devices
- No PLC code or function blocks required
- Compatible with PLCs from all leading manufacturers
- Versions with Dual Port switched Ethernet allows for daisy-chaining and eliminates the need for external switches
- High performance, fast throughput, max 5 ms
- Anybus Configuration Manager included for easy visual CAN frame building
- Dynamic transaction controlled by the network master
- Global free technical support and consultancy
The Anybus Configuration Manager (ACM) is included with the purchase of the Anybus Communicator.
- Graphical CAN frame building support using several ready-made CAN functions.
- Can configure any CAN 2.0A or 2.0B based protocol (11 and 29-bit identifiers).
- Configures up to 128 transactions containing a total of 256 CAN frames
- Monitor/Modify function of process I/O data informing of the CAN transaction status
- Diagnostic transaction Live List in the network I/O informing of the CAN transaction status
- Multi-language support, supporting English, German, Spanish, Italian, French, Polish, Russian, Chinese, and Japanese
- Handy Save/Load function allows for a completed configuration to be re-used for many other installations
- Password protection prevents unauthorised upload and download of configurations
- Complete CANopen slave functionality according to CANopen Version 4.02
- Max 512 bytes of Input and 512 bytes of Output data (PDO + SDO)
- Customizable PDO mapping
- Up to 80 RPDO’s and 80 TPDO’s
- Transmission types: PDO Sync, Change-of-state, Event-based and RTR
- Network store/restore functionality
- Heartbeat & Node Guarding support
- Supports CANopen baud rates 10 kbit/s – 1 Mbit/s
- CANopen configuration via .EDS file or DIP switches
- 1x D-sub 9-pin male CANopen connector
Communicator CAN
Protocol | Configurable CAN 1.0, 2.0A and 2.0B based protocols |
Baud rate | 20 kbit/s – 1 Mbit/s |
Physical standards | CAN |
Technical Details
Dimensions (L x W x H) | 120 x 75 x 27 mm 4,72 x 2,95 x 1,06” |
|
Weight | 150 grams, 0.33 lb | |
Protection class | IP20 Nema rating 1 | |
Enclosure material | PC ABS, UL 94 | |
Installation position | Any | |
Mounting | DIN rail (35 * 7,5/15) | EN 50022 |
Certifications
UL | File Number: E203225 | UL 508 Ind. Cont. Eq. |
Hazardous Locations | CLASS 1, DIVISION 2, GROUPS A, B, C, AND D, T4 | ANSI/ISA-12.12.01-2000 |
CE | 2004/108/EC | EN 61000-6-4 EN 61000-6-2 |
ATEX | Zone 2, Cat 3 (except Modbus RTU) | EN 60079-11 EN 60079-15 |
Electrical characteristics
Power | 24 VDC +/- 10 % |
Current consumption | Max 300 mA, Typical 100 mA |
Hardware characteristics
Reverse voltage protection | Yes | |
Short circuit protection | Yes | |
Galvanic isolation on the subnetwork | Yes | EN 60950-1 |
Environmental characteristics
Operating temp | -25 to 55 o C, -13 to 131 o F | IEC 60068-2-1 IEC 60068-2-2 |
Storage temp | -40 to 85 o C, -40 to 185 o F | IEC 60068-2-1 IEC 60068-2-2 |
Relative Humidity | 5-95% non condensing | IEC 60068-2-30 |
Installation altitude | Up to 2 000 m | |
Immunity and emission for the industrial environment
Electrostatic discharge | +/- 4 kV | EN 61000-4-2 |
Electromagnetic RF fields | 10 V/m 80 MHz – 1 GHz 3 V/m 1,4 GHz – 2,0 GHz 1 V/m 2,0 GHz – 2,7 GHz |
EN 61000-4-3 |
Fast Transients | +/- 1 kV | EN 61000-4-4 |
Surge protection | +/- 1 kV | EN 61000-4-5 |
RF conducted interference | 10 V/rms | EN 61000-4-6 |
Emission (at 10 m) | 40 dB 30 MHz – 230 MHz 47 dB 30 MHz – 1 GHz |
CISPR 16-2-3 |
Order Code: AB7315
Included Components:
- Quickstart documentation
- USB configuration cable
- CAN D-sub connector is supplied with every single-piece Communicator shipment
- All configuration software available for download
- (Power supply not included)
Guarantee: 3 years
Book your product
We are fully committed to providing our customers with the very best products and customer service. We believe in going the extra mile to ensure that each customer is satisfied with our products and solutions. We have the experience and the reputation in the field to deliver the products customers need to expedite their projects and assure quality every step of the way.
Our expertise lies in establishing, maintaining, and leveraging plant data for business benefit. Through our innovative solutions, we work alongside you to streamline processes, enhance efficiency, and reduce costly downtime.
Copyright @2024 Industrial Data Xchange.
All rights reserved.
CONTACT US
Main: +27 (11) 548 9960
Sales: +27 (11) 548 9970
SOCIAL MEDIA