Seamlessly inter-connect PLC control systems and their connected devices between CC-Link and Modbus RTU networks.
FAST COPYING OF I/O DATA
The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as a Slave on both networks. The data transmission is completely transparent with a maximum data capacity of 512 bytes in each direction.
Easy Configuration – No programming required!
The connection between the two networks is configured with the “Anybus Configuration Manager” software. No programming skills are required for this. The amount of I / O data to be transferred is preset to 20 bytes at the factory.
Product Information
- Fast exchange of cyclic I / O data between the two networks (10-15 ms)
- Compatible with PLCs from leading manufacturers
- Supports up to 512 bytes of input and output data in each direction
- Control and status information can be added to the I / O data for diagnostic purposes
- Robust stand-alone housing for use in harsh industrial environments
- Qualified, personal support
You can either set the CC-Link slave settings directly on the gateway using switches or import the .CSP file provided by HMS into the PLC’s engineering tool.
- Full-fledged CC-Link slave according to version 1 and 2
- CC-Link compliant according to specification BTP-05027-B
- Transparent CC-Link communication (mode: Standard)
- Communication according to the PLC profile (mode: PLC profile)
- Max. 896 bits / 128 words (368 bytes) I / O data in each direction
- Supports CC-Link baud rates of 156 kbit / s – 10 Mbit / s
- Up to 4 occupied stations
- Supports extended cycle time (only version 2)
- CC-Link configuration via switch or .CSP file
- 1 x 5-pin, 5.08 Phoenix Contact network connection
The address settings for the Modbus RTU network are made using configuration switches.
- Complete Modbus RTU slave functionality
- Max. 512 bytes of input and 512 bytes of output data
- Modbus diagnosis is supported
- Configuration via DIP switch
- Modbus RTU baud rate: 12 – 57.6 kbit / s
- Network connection: 1 x 9-pin D-Sub socket
Dimensions (L • W • H) | 114 x 44 x 127 mm or 4.49 x 1.73 x 5.00 “ |
Weight | 400 g or 0.880 lbs |
operating temperatur | -25 to +65 ° C or -13 to +149 ° F |
Storage temperature | -40 to +85 ° C or -40 to +185 ° F |
Power supply | 24 VDC +/- 20% via 2-pin 5.08 mm Phoenix screw terminal connection |
Power consumption |
Max. 400 mA (typically 200 mA) |
Housing material | Aluminum and plastic |
Mounting position | Vertical / flat * |
Galvanic separation | YES, on both BUS / Ethernet sides |
Protection class | IP20, NEMA rating 1 |
Assembly | DIN rail (EN 50022 standard) |
I / O configuration | Via USB port and the “Anybus Configuration Manager” software |
Certifications | CE, C UL US , ATEX / Haz.Loc, RoHS |
Order Code | AB7500 |
---|---|
Included components | Gateway Quick start documentation USB configuration cable Serial cable for PROFIBUS master configuration Resource CD with PROFIBUS master configuration software Power supply not included Configuration and Anybus OPC server software is available for download. |
Book your product
We are fully committed to providing our customers with the very best products and customer service. We believe in going the extra mile to ensure that each customer is satisfied with our products and solutions. We have the experience and the reputation in the field to deliver the products customers need to expedite their projects and assure quality every step of the way.