Select Page

Specifically designed to allow bidirectional control and monitoring of all parameters and functionalities of your building automation projects

This bidirectional gateway provides a straightforward and fast integration thanks to its unique onboard features. Thanks to its support for both Modbus RTU and TCP, with the possibility to work together at the same time, seamless integration with any Modbus BMS or controller it is guaranteed.

The configuration is carried out using the Intesis MAPS software. This one allows you to define your own settings for the device. Also, it will be able to download all the available project templates or to import any created/exported project template on your computer.

Integrate any M-Bus device with a Modbus BMS or any Modbus TCP or Modbus RTU controller. The aim of this integration is to make accessible M-Bus devices, their registers, and resources from a Modbus based control system or device as if it was a part of the own Modbus system and vice-versa.

M-Bus Protocol Translators

Provide metering information to your BACnet, KNX, or Modbus management system. Electricity, water, energy, or gas meters, among others, can be easily integrated into your building management or control system thanks to Intesis M-Bus gateways.

Intesis M-BUS acts as a level converter and as a Master device in its M-Bus interface. It polls, either continuously or when ordered, the M-Bus meters to obtain updated readings for the points configured.

Bus scan register discovery and device templates make the configuration process fast and easy.

  • Easy integration through KNX TP, BACnet, or Modbus protocols.
  • Automatic assignment of units and conversions for M-BUS to BACnet and KNX gateways.
  • Scaled licenses per number of M-BUS devices help to find the right gateway version for your project.

Embedded M-Bus level converter

No additional hardware is needed as the required M-Bus level converter is already embedded.

Bus scan

Discover all M-BUS devices connected to its channel and import them in an easy way.

Register Discovery

Discover all data available in an M-Bus device and import it easily and efficiently to your integration project.

M-Bus template generator

Create your own templates, share them between projects, or use one of the templates Intesis offers downloading directly from MAPS.

Modbus Protocol Translators

Bring connectivity to your Modbus management system thanks to Intesis Modbus solutions. Connect BACnet, KNX, LonWorks, DALI, or M-BUS devices to Modbus systems and extend your building management system capabilities.

Intesis Modbus can act as a Modbus RTU device, Modbus TCP device, or both.

On the Modbus server versions, the gateway provides server functionality to the BMS or Modbus controller over Modbus TCP through the Ethernet port and over Modbus RTU through the serial port (EIA485 or EIA232).

On the Modbus client versions, the gateway provides client functionality to control Modbus TCP server devices through Ethernet and Modbus RTU devices through the serial port. In such cases, control and monitoring of Modbus devices from BACnet and KNX BMS controllers is possible.

  • Great integration flexibility thanks to KNX TP, RS485, Ethernet, DALI, or M-Bus interfaces.
  • Scaled licenses per number of datapoints help to find the right gateway version for your project.
  • Modbus advanced functionalities to improve internal and external protocol communications.
  • Modbus template repository with most common Modbus devices and template generator to create your own template devices.

Modbus TCP & RTU

All Modbus gateways can communicate with Modbus TCP and RTU networks at the same time.

Most I/O Modbus functions supported

Use any I/O function code of the wide range supported by Modbus gateways (1x, 2x, 3x, 4x, 5x, 6x, 15x, and 16x).

Multiple data formats

Configure the data length (1, 16, 32, 48, or 64 bits), format (unsigned, signed, float, and bitfield), and byte order (big or little-endian).

Polling groups

Improve Modbus communications grouping register requests per device, asking multiple registers in a single request.

Product Information

  • UL Certified
  • Support for up to 5 simultaneous Modbus TCP Clients
  • Both Modbus RTU & Modbus TCP
  • M-BUS line scan (meter detection) and register discovery
  • Embedded M-Bus level converter
  • Easy integration & updates with Intesis MAPS
ORDER CODES: 

INMBSMEB0100000  M-BUS to Modbus TCP & RTU Server Gateway – 10 devices
INMBSMEB0200000  M-BUS to Modbus TCP & RTU Server Gateway – 20 devices
INMBSMEB0600000  M-BUS to Modbus TCP & RTU Server Gateway – 60 devices
INMBSMEB1200000  M-BUS to Modbus TCP & RTU Server Gateway – 120 devices
  • Intesis Gateway.
  • Installation Manual.
  • USB Configuration cable.
  • (Power supply not included).
  • Warranty: 36 months.

Book your product

We are fully committed to providing our customers with the very best products and customer service. We believe in going the extra mile to ensure that each customer is satisfied with our products and solutions. We have the experience and the reputation in the field to deliver the products customers need to expedite their projects and assure quality every step of the way.