Select Page

Seamlessly inter-connect PLC control systems and their connected devices between PROFINET-IRT and PROFIBUS networks.

FAST COPYING OF I/O DATA
The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as an Device/Slave on both networks. The data transmission is completely transparent with a maximum data capacity of 512 bytes in each direction.

Easy Configuration – No programming required!

The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default, the X-gateways have a pre-defined I/O size of 20 bytes I/O.

Product Information

  • PROFIBUS Slave settings can be made either via on-board switches, or by importing the provided .GSD file into engineering tool of the controlling PLC. 

    • Complete PROFIBUS-DP/DPV1 Slave functionality according to extensions of EN 50170
    • Supports Class 1 & Class 2 services
    • Automatic baudrate detection up to 12Mbit/s
    • Max. Cyclic I/O data 244 bytes Input and 244 bytes Output, max 344 bytes total (in+out)
    • Acyclic User Parameter data / Diagnostics length – up to 237 bytes
    • Supports PROFIBUS features: Sync and Freeze and Watchdog
    • PROFIBUS slave settings via on-board switches or vis .GSD file
    • 1x D-sub 9-pin female PROFIBUS connector

PROFIBUS Slave settings can be made either via on-board switches, or by importing the provided .GSD file into engineering tool of the controlling PLC. 

  • Complete PROFIBUS-DP/DPV1 Slave functionality according to extensions of EN 50170
  • Supports Class 1 & Class 2 services
  • Automatic baudrate detection up to 12Mbit/s
  • Max. Cyclic I/O data 244 bytes Input and 244 bytes Output, max 344 bytes total (in+out)
  • Acyclic User Parameter data / Diagnostics length – up to 237 bytes
  • Supports PROFIBUS features: Sync and Freeze and Watchdog
  • PROFIBUS slave settings via on-board switches or vis .GSD file
  • 1x D-sub 9-pin female PROFIBUS connector

PROFINET IRT F.Optic  Device/Slave settings can be made either via the built-in web interface, or by importing the provided .GSDML file into engineering tool of the controlling PLC. 

  • Complete PROFINET-IRT Isochronous -Real-Time (IRT) communication
  • Max 220 bytes of Input and 220 bytes of Output data
  • Acyclic Data exchange (Record Data Requests)
  • Up to 17 slots / up to 4 subslots per slot (1 by default)
  • Baud rate 100 Mbit/s fixed
  • Integrated FTP server provides easy file management using standard FTP clients
  • Web server with dynamic data capability and Server Side Include (SSI) capability
  • Email client with dynamic data capability and Event-triggered email handling
  • Built in file system with per-user security framework
  • SNMP-MIBII support
  • Modbus-TCP server (read-only)
  • TCP/IP Configuration via DCP (Discovery and Configuration Protocol)
  • LLDP (Linked Layer Discovery Protocol)
  • Support for I&M (Identification & Maintenance )
  • PROFINET uplink configuration via .GSDML file
  • Integrated switch allowing for a daisy-chain topology
  • 2x SC-RJ Fiber Optic network connectors available simultaneously 
  • Supports PROFINET RT and IRT functionality specification 2.3
  • Conformance tested supporting Class A, B and C
Dimensions (L•W•H)   114 x 44 x 127mm or 4,49 x 1,73 x 5,00″
Weight 400g or 0,880 lbs
Operating temperature -25 to +65 °C  or  -13 to +149 °F 
Storage temperature -40 to +85 °C  or  -40 to +185 °F 
Power supply 24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
Current consumption     max. 400mA (Typical 200mA)
Enclosure material  Aluminium and plastic
Installation position Vertical / Flat*
Galvanic isolation YES, on both BUS/Ethernet side
Mechanical rating IP20, NEMA rating 1
Mounting DIN-rail (EN 50022 standard)
I/O configuration via USB port with Anybus Configuration Manager software
Certifications CE, CULUSRoHS
Order Code  AB7508
Included components            

Gateway
Quick start documentation
USB configuration cable

Power supply not included

Configuration and Anybus OPC server software is available for download.

Book your product

We are fully committed to providing our customers with the very best products and customer service. We believe in going the extra mile to ensure that each customer is satisfied with our products and solutions. We have the experience and the reputation in the field to deliver the products customers need to expedite their projects and assure quality every step of the way.

Our expertise lies in establishing, maintaining, and leveraging plant data for business benefit. Through our innovative solutions, we work alongside you to streamline processes, enhance efficiency, and reduce costly downtime.

CONTACT US

Main: +27 (11) 548 9960
Sales: +27 (11) 548 9970

SOCIAL MEDIA

Copyright @2024 Industrial Data Xchange. All rights reserved.